Description
The Auto Shield LED skylight dome roof vent is ideal accessory form the motorhome, camper van or horse box which require additional ventilation and light. It’s also ideal for venting small spaces. Made from superior quality impact and UV resistant materials supplied with blackout blinds and flynet screen.
Sizes quoted are approximates please see exact sizes below in specification.
- Ideal for campervans / vans / motorhomes / showers / sanitations areas /outbuildings / shed / barn
- Easy operation with gas lift struts
- Fitted with LED lights and switch
- Interior frame with black out blinds and flynet screen
- Double glazed dome top·
- Maximum opening to an angle of 60deg.·
- Up to 150 cubic center meters of permanent ventilation.
Specification:
- Product code : SKY.450×400.LED
- Overall size(mm):587*578
- Cut out size(mm) : 452*402
- R angle: R15
- Above the roof (mm):98
- Wall thickness(mm):25-60
- Description :With LED and Switch
- Power(w):4.6
- Weight(kg):5.6
Please note: Pictures are for illustration purposes only, colour / shade may vary depending on the device you view on.
Instructions to fit:
- Place the internal cap (garnish) on top the roof and draw a template using a felt tip, then add another 5mm to the top and left side.
- Drill pilot holes in each corner and cut along the template line. Be certain to avoid ribs, braces, and electrical wiring (internally).
- Check that the internal cap fits through the aperture If not, cut out opening as needed and then smooth down any rough edges and primer the exposed with metal oxide paint.
- Make a wooden frame around the aperture to the thickness of the interned finish depth required, taking in to account the roof ply and lining.
- Glue the frame with Shield Stick and Seal (polyurethane) and clap in place and allow the adhesive to set.
- Screw the internal cap to the timber frame and seal around the lip from the top of the roof using flexible putty or Sikaflex.
- Place the external vent over the lip of the internal cap and mark the screw holes with a center punch. Then remove vent from roof and drill all screw hole locations with a 1/16’’ pilot hole, and seal with primer paint. NOTE: If installing a power or lighted vent, provide power source of 12 volts DC, using 18-gauge wire.
- Place putty strips/ Sikaflex flex bead around the opening on roof ½’’ (1.27cm) from edge of opening. (Be sure putty strips cover entire area to be sealed.) Use double layers of putty strip or extra Sikaflex if necessary, to seal ribbed areas.
- Insert vent into opening on top of putty strips.
- Use an screw driver or nail to locate and line up corner drilled holes with the corner screw holes in vent frame. CAUTION: Install vent with lid hinge side toward front of vehicle. Screw corner screws first to hold vent in place then screw all remaining vent mounting screws. Tighten just enough to compress putty tape. Over-tightening may cause Plastic Base Vents to crack.
- Using the appropriate roof coating for your roof surface, coat screw heads and vent frame edge and seal around the frame if necessary.
- Your installation is complete
If you are retrospectively fitting the roof vent you must take care when cutting the aperture as not to damage the existing head lining and leave enough to cover the timber frame if required.